Dropout voltage and input limits — what they mean for your rail budget
The 0.145 V maximum dropout at 3 A is the key number for rail budgeting. The fixed output is 1.25 V, and the absolute maximum input is 1.98 V.
Lifecycle and sourcing
The ADP1763WACPZ1.25-R7 carries an Active lifecycle status and is ROHS3 compliant. No end-of-life notice or last-time-buy schedule is in effect, so it can be specified into new production BOMs without obsolescence risk. The part is available through independent distribution; pricing and stock levels are confirmed at quote time against an RFQ. For dual-sourcing, the standard ADP1763ACPZ-1.2-R7 and ADP1763ACPZ-1.1-R7 are pin-compatible siblings at different fixed output voltages (1.2 V and 1.1 V respectively), sharing the same package, dropout, and protection features — they can serve as alternate BOM entries if the output voltage tolerance allows.