Siemens 3RV20111FA20 Motor Protection Circuit Breaker
MPN Structure and Catalog Context
The prefix 3RV identifies this as a Siemens SIRIUS motor protection circuit breaker. Within the 3RV2011 family (S00 size), the designation breaks down as follows: 3RV20-111-FA20 — "111" denotes three-pole thermal type with rotary handle; "FA20" specifies the 3.5–5 A current range with spring-clamp load-side terminals. The seed record shows a bulk-packaged unit without auxiliary contacts; in-catalog variants add screw-type terminals, ring-lug terminations, and auxiliary contact configurations under the same thermal/frame architecture.
The 3RV2011 series occupies the S00 (45 mm width) frame within Siemens' SIRIUS motor protection portfolio. These devices serve as direct-on-line motor starters and feeder breakers in control cabinet layouts.
Key Specifications
| Parameter | Value |
|---|---|
| Current Rating | 5 A |
| Breaker Type | Thermal |
| Number of Poles | 3 |
| Actuator Type | Rotary |
| Mounting Type | DIN Rail |
| Illumination | None |
| Encapsulation | Bulk |
| Approval Agencies | ATEX, CCC, CSA, EAC, IECEx, UL |
| Product Status | Active |
The voltage rating and short-circuit breaking capacity are not stated in the current catalog records; those parameters are not covered in this specification.
Comparative Analysis of 3RV2011 In-Catalog Variants
Parameter Similarity Table (shared spec keys)
| MPN | Current | Breaker Type | Actuator | Mounting | Poles | Illumination | Approval Agencies | Encapsulation | Similarity |
|---|---|---|---|---|---|---|---|---|---|
| 3RV20111FA20 | 5 A | Thermal | Rotary | DIN Rail | 3 | None | ATEX, CCC, CSA, EAC, IECEx, UL | Bulk | — |
| 3RV20111FA25 | 5 A | Thermal Magnetic | Rotary | DIN Rail | 3 | None | ATEX, CCC, CE, CSA, EAC, IECEx, UL, VDE | Box | 1.0 |
| 3RV20111FA40 | 5 A | Thermal Magnetic | Rotary | DIN Rail | 3 | None | ATEX, CCC, CE, CSA, EAC, IECEx, UL, VDE | Box | 1.0 |
| 3RV20111FA10 | 5 A | Thermal | Rotary | DIN Rail | 3 | None | ATEX, CCC, CSA, EAC, IECEx, UL | Bulk | 1.0 |
| 3RV20111FA15 | 5 A | Thermal | Rotary | DIN Rail | 3 | None | ATEX, CCC, CSA, EAC, IECEx, UL | Bulk | 1.0 |
| 3RV20111FA150BA0 | 5 A | Thermal Magnetic | Rotary | DIN Rail | 3 | None | CE, EAC, VDE | Box | 1.0 |
| 3RV20111FA100BA0 | 5 A | Thermal Magnetic | Rotary | DIN Rail | 3 | None | CE, EAC, VDE | Box | 1.0 |
| 3RV20111CA20 | 2.5 A | Thermal | Rotary | DIN Rail | 3 | None | ATEX, CCC, CSA, EAC, IECEx, UL | Bulk | 0.92 |
| 3RV20111EA20 | 4 A | Thermal | Rotary | DIN Rail | 3 | None | ATEX, CCC, CSA, EAC, IECEx, UL | Bulk | 0.92 |
Why the Top Similar Variants Match
3RV20111FA25 — Shares identical current rating, 3-pole rotary-actuator DIN Rail architecture. Adds auxiliary contacts (1NO+1NC) and thermal-magnetic construction versus the seed's thermal-only design; expanded approval coverage includes CE and VDE. The box encapsulation reflects a package format difference rather than a functional distinction in the protection mechanism.
3RV20111FA40 — Matches the seed on all primary protection parameters (5 A, 3-pole, rotary, thermal magnetic). Title references ring-lug load-side connection; the shared spec keys do not capture termination type, so direct comparison on that axis is not possible from this record.
3RV20111FA10 — Retains the seed's thermal-only breaker type and bulk encapsulation while dropping any auxiliary contact configuration. Both devices share identical approval agency coverage and physical form factor.
Selection Trade-offs
- Spring-clamp (FA20) versus screw-terminal (FA10) load-side connections affect wiring practice and tool requirements — spring-clamp allows tool-free conductor insertion within the rated cross-section range.
- Thermal-only (FA20, FA10, FA15) versus thermal-magnetic (FA25, FA40, FA150BA0, FA100BA0) impacts coordination with downstream motor thermal overload relay settings in direct-on-line arrangements.
- Bulk packaging suits high-volume panel assembly; box encapsulation may simplify single-unit procurement and storage.
- Auxiliary contact availability (FA25, FA15) supports feedback signal paths for status monitoring or interlock logic without additional enclosure footprint.
- Global certification breadth (ATEX, CCC, CSA, EAC, IECEx, UL) covers most industrial export markets; the BA0 variants restrict to CE/EAC/VDE, which may limit multinational deployments.
FAQ
What is the current range for 3RV20111FA20?
The catalog record shows a 5 A rating. The product family spans 1.8–5 A across the 3RV2011 series variants, but only the 5 A rating is on record for this specific MPN.
Does 3RV20111FA20 include auxiliary contacts?
No. The seed MPN is a basic unit without auxiliary contacts. Variants such as 3RV20111FA25 and 3RV20111FA15 include 1NO+1NC auxiliary contacts under the same 45 mm S00 frame.
What approval agencies apply to 3RV20111FA20?
ATEX, CCC, CSA, EAC, IECEx, and UL are listed for the seed. Several in-catalog variants add CE and VDE certifications — confirm against the specific MPN required for a given installation region.