Siemens 3RT20241AN24 Contactors
Overview
The Siemens 3RT20241AN24 is a size S00 electromechanical contactor in the 3RT2 series, delivering a 12 A three-pole main switching structure with a 220 VAC coil and two integrated auxiliary contacts (2NO + 2NC). The MPN prefix 3RT2024 places this firmly in Siemens' standard industrial contactor family (3RT2 / Sirius) intended for motor and load control in AC-1 and AC-3 applications; the AN suffix encodes the contact arrangement and voltage class ("N" = 220 VAC 50/60 Hz), and 24 is the size/style digit. The title states "S0" (S00), which aligns with the compact 45 mm width rail-mount form factor typical of that size class, though exact mechanical dimensions are not provided in the catalog fields. Key catalog-derived parameters are summarized below.
Key Parameters
| Parameter | Catalog Value | Notes |
|---|---|---|
| Base Product Number | 3RT2024 | Shared across all 3RT2024 variants listed |
| Contact Form | 3PST-NO (3 Form A) per specs field | Title states "2NO/2NC"; mismatch — see Verification callout |
| Contact Rating | 12 A | AC-1/AC-3 ratings must be confirmed on datasheet |
| Coil Voltage | 220 VAC | Must-operate: 187 VAC |
| Coil Power | 67 VA | Inrush/seal values may differ per datasheet |
| Operate Time | 40 ms | Release time not listed |
| Operating Temperature | 25°C ~ 60°C | Restricted range; full industrial range may be wider |
| Mounting | Chassis Mount, DIN Rail | Compatible with TH35-7.5 or TH35-15 DIN rail per Sirius practice |
| Features | Auxiliary Contacts | Specific count confirmed only in title (2NO/2NC) |
| Encapsulation | Box | Unit pack; alternate variants ship in bulk |
⚠ Verification required: Electrical ratings critical for branch protection coordination — AC-1 current, AC-3 horse-power rating, making/breaking capacity, dielectric withstand, and contact wear ratings — are not present in the supplied fields. Selection must not proceed on electrical ratings until verified against the official Siemens Sirius 3RT2 datasheet.
Integration / Installation Notes
The 3RT20241AN24 is a DIN-rail-mountable contactor intended for motor branch and general-load switching in industrial enclosures.
- Terminal style and wire size are not listed in the catalog fields; these must come from the datasheet.
- IP rating / enclosure requirements are not stated; installation in a suitable enclosure is implied but not specified.
- ** DIN rail compatibility** (TH35-7.5 or TH35-15) is consistent with standard Sirius practice, but physical cutout/flange dimensions should be confirmed.
- Auxiliary contact block is integral; no separate add-on block is specified as needed for the 2NO/2NC configuration.
The catalog data does not specify: torque settings, maximum switching voltage, Electrical Life (cycles), Mechanical Life (cycles), or coil inrush vs seal power separately.
Selection / Substitution Guidance
Substitution of the 3RT20241AN24 with any listed alternate requires datasheet-level validation across the following dimensions:
- Coil voltage — must match the control system exactly; coil mismatch will cause failure to pull in or coil burnout.
- Auxiliary contact count and type — the seed specifies 2NO/2NC; alternates with 1NO/1NC (3RT20241AN20, 3RT20241AL20) cannot substitute in circuits requiring both normal-open and normal-closed auxiliary signals.
- Must-operate voltage — differs between coil voltage classes; selecting a lower-voltage coil variant (24 VAC, 110 VAC) for a 220 VAC circuit will result in non-operation.
- Operating temperature — the catalog states 25°C to 60°C; full datasheet may allow -25°C to +60°C for industrial use; cold-environment applications require confirmation.
- Mechanical envelope — all listed parts share base number 3RT2024 and should have the same foot print, but packaging (Box vs Bulk) does not affect fit.
Similar Catalog Parts
| MPN | Coil Voltage | Must Operate | Contact Config | Coil Power | Operate Time | Operating Temp | Similarity |
|---|---|---|---|---|---|---|---|
| 3RT20241AN24 (seed) | 220 VAC | 187 VAC | 2NO/2NC | 67 VA | 40 ms | 25°C ~ 60°C | — |
| 3RT20241AN20 | 220 VAC | 187 VAC | 1NO/1NC | 68 VA | 38 ms | 25°C ~ 60°C | 1.00 |
| 3RT20241AN60 | 200 VAC | — | 2NO/2NC | 67 VA | 40 ms | 25°C ~ 60°C | 1.00 |
| 3RT20241AL24 | 230 VAC | 195.5 VAC | 1NO/1NC | 67 VA | 40 ms | 25°C~60°C | 0.96 |
| 3RT20241AC24 | 24 VAC | 20.4 VAC | 2NO/2NC | 67 VA | 40 ms | 25°C~60°C | 0.96 |
| 3RT20241AG24 | 110 VAC | 93.5 VAC | 2NO/2NC | 67 VA | 40 ms | 25°C~60°C | 0.96 |
| 3RT20241AK64 | 120 VAC | 96 VAC | 2NO/2NC | 67 VA | 40 ms | 25°C~60°C | 0.96 |
| 3RT20241AF04 | 110 VAC | 88 VAC | 2NO/2NC | 65 VA | 40 ms | 25°C~60°C | 0.96 |
| 3RT20241AL20 | 230 VAC | 195.5 VAC | 1NO/1NC | 67 VA | 40 ms | 25°C~60°C | 0.96 |
Why they are similar: All nine parts share base number 3RT2024, 12 A contact rating, 3PST-NO main pole structure, auxiliary contact feature, and DIN-rail/chassis mounting. They differ primarily in coil voltage class and auxiliary contact count, which are the primary selection differentiators within the Sirius S00 family.
- 3RT20241AN20 — Same coil voltage and must-operate as the seed; identical in all listed parameters except auxiliary contacts reduced to 1NO/1NC and operate time 38 ms vs 40 ms. Valid substitute only for circuits not requiring the second set of auxiliary contacts.
- 3RT20241AN60 — Same mechanical and contact spec; coil voltage class 200 VAC (must-operate not listed in catalog). Verify must-operate is compatible with the control circuit before use.
- 3RT20241AL24 — 230 VAC coil with must-operate 195.5 VAC; auxiliary contacts reduced to 1NO/1NC; cannot substitute where 2NC is required for protection wiring.
- 3RT20241AC24 — 24 VAC coil class (must-operate 20.4 VAC); maintains 2NO/2NC auxiliary config. Not interchangeable with 220 VAC coil without control power change.
- 3RT20241AG24 / AK64 / AF04 — 110 VAC and 120 VAC coil variants; all retain 2NO/2NC auxiliary config except AF04. Cannot substitute on a 220 VAC control circuit without coil replacement or control power conversion.
FAQ
Q: What is the difference between the 3RT20241AN24 and the 3RT20241AN20? A: Both are 220 VAC coil contactors with identical main pole ratings (12 A, 3PST-NO). The seed (3RT20241AN24) provides 2NO/2NC auxiliary contacts, while the 3RT20241AN20 provides only 1NO/1NC. If the application relies on two auxiliary contacts in a specific configuration, the AN24 is required; otherwise the AN20 may be substituted after verifying wiring compatibility.
Q: Can a 230 VAC coil contactor such as the 3RT20241AL24 substitute for the 3RT20241AN24 on a 220 VAC control system? A: No. The 3RT20241AL24 requires 230 VAC nominal with a must-operate voltage of 195.5 VAC. A nominal 220 VAC control system (220–240 V range depending on supply tolerance) may not reliably pull in the 230 VAC coil. Coil voltage must match the control circuit; do not substitute across voltage classes without evaluating control supply tolerance.
Q: Are the main pole current ratings of the 3RT20241AN24 sufficient for motor starting (AC-3)? A: The catalog lists a contact rating of 12 A but does not specify whether this is AC-1 (non-inductive), AC-3 (motor starting), or another utilization category. AC-3 rating at a given voltage is typically lower than AC-1. Before specifying for motor starting duty, confirm the AC-3 HP/kW rating and making/breaking currents from the Siemens Sirius 3RT2 datasheet.