Skip to main content
Siemens

Siemens 3RT20161AN21 S00-Size Contactors

In a motor branch or lighting feeder circuit, the 3RT20161AN21 occupies the S00 frame position—smallest in the Siemens power-contactor lineup—and provides three normally-open power poles plus an auxiliary-contact function. The catalog entry records a 220 VAC coil, a 9 A contact rating, and a 35 ms operate time; the ...

Siemens 3RT20161AN21 S00-Size Contactors

Overview

In a motor branch or lighting feeder circuit, the 3RT20161AN21 occupies the S00 frame position—smallest in the Siemens power-contactor lineup—and provides three normally-open power poles plus an auxiliary-contact function. The catalog entry records a 220 VAC coil, a 9 A contact rating, and a 35 ms operate time; the 3RT2016 base number is shared across the entire S00 three-phase contactor family.

Verification required — The data source does not provide: breaking capacity (I_c / Icu / Ics), electrical endurance cycles, mechanical endurance cycles, switching voltage limits, coil release/drop-out voltage, weight, overall dimensions, terminal detail, or IP / protection-class ratings. These are mandatory for coordination studies and panel layout. Do not select on the fields below alone.

Key Parameters

ParameterValue (from JSON)Notes
Base Product Number3RT2016Shared by all S00-size three-phase contactors in this series
Contact Rating (Current)9 AAC-3 utilization category not confirmed in supplied fields
Contact Form3PST-NO (3 Form A)Three independent normally-open power poles
Coil Voltage220 VACVerify mains compatibility before wiring
Coil Power24.3 VAInrush apparent power; release power not in data
Must Operate Voltage187 VACCoil pulls in at ≤ 187 VAC; drop-out threshold not listed
Operate Time35 msPick-up delay; release time not supplied
Operating Temperature25°C ~ 60°CNo cold-temperature limit provided
Mounting TypeChassis Mount, DIN RailS00 form factor; enclosure / IP rating not specified
EncapsulationBoxSuggests standard shipped configuration; verify with datasheet
FeaturesAuxiliary ContactsOne auxiliary contact integrated; normally-open or normally-closed state not specified in supplied fields

Ordering-Code / Family Context

The prefix 3RT20 denotes Siemens power contactors in the S00 size class (frame designation 00 per IEC 60947-1). The characters following encode coil voltage and auxiliary-contact arrangement. Without the full Siemens ordering-code tables, the suffix 1AN21 cannot be decoded into exact auxiliary-contact type and verification of AC-3 / AC-1 ratings must come from the official datasheet. The listed alternates share the same base number and mounting form factor but differ in coil voltage or auxiliary-contact polarity.

Installation Notes (Generic — Verify with Datasheet)

The S00 contactors are typically panel-mounted on DIN rail or direct chassis; the catalog confirms both mounting options exist. Key items not confirmed in the supplied fields:

  • Overall dimensions and fixing-centre distances
  • Terminal screw size and tightening torque
  • Acceptable wire gauge and stranding
  • Required clearance to adjacent devices
  • IP rating of the installed assembly

Selection Considerations

  • Coil voltage match — Confirm the 220 VAC coil matches the available control-circuit voltage. The must-operate voltage (187 VAC) sets the lower bound; the drop-out voltage is absent and must be confirmed.
  • Auxiliary contact state — The title reads "1NO" (one normally open); the specs list "Features: Auxiliary Contacts" without specifying NO/NC polarity. Verify before wiring interlock or indication circuits.
  • Current derating — The 9 A rating is stated without an explicit utilization category. Siemens S00 contactors commonly carry AC-3 ratings; the absence of this designation means selection should not proceed without confirming the intended duty (AC-1, AC-3, DC, or resistive/heating).
  • Operating temperature — The range 25°C ~ 60°C is narrow; no lower limit is listed. Cold-climate installations require datasheet confirmation.
  • Coordination — Breaking capacity and short-circuit protective device coordination data are not in the supplied fields; this is a critical gap for motor feeder design.

Similar Catalog Parts

Primary vs AlternateShared Spec KeysCoil VoltageContact RatingOperate TimeSimilarity (0–1)
3RT20161AN21 vs 3RT20161AN22Base Product Number, Coil Power, Contact Form, Mounting Type, Must Operate Voltage, Operate Time, Operating Temperature220 VAC (both)9 A (both)35 ms (both)1.00
3RT20161AN21 vs 3RT20161AN61Contact Rating, Contact Form, Mounting Type, Must Operate Voltage, Operate Time220 vs 200 VAC9 A (both)35 ms (both)1.00
3RT20161AN21 vs 3RT20161AK21Base Product Number, Coil Power, Contact Rating, Contact Form, Mounting Type, Operate Time220 vs 120 VAC9 A (both)35 ms (both)0.96

Why they are similar

  • 3RT20161AN22 (similarity 1.00): Shares the same 220 VAC coil and S00 frame; the catalog title indicates a 1NC auxiliary contact versus the primary's 1NO. The reason string references shared parameters across the full series. The auxiliary-contact polarity difference must be verified if the interlock logic depends on normally-open versus normally-closed state.
  • 3RT20161AN61 (similarity 1.00): Matches the primary in form factor and current rating but uses a 200 VAC coil (coil power 26.4 VA vs 24.3 VA) and ships in bulk packaging. Not a drop-in substitute where 220 VAC control power is specified.
  • 3RT20161AK21 (similarity 0.96): Same base and 9 A rating; coil voltage is 120 VAC (must-operate 102 VAC). Useful if a lower control voltage is available; verify that the 187 VAC must-operate spec does not apply.

FAQ

Q: What is the breaking capacity of the 3RT20161AN21 when used in a motor feeder? A: The supplied catalog fields do not include I_c, Icu, or Ics ratings. The breaking capacity must be obtained from the Siemens 3RT2016 datasheet for coordination and short-circuit withstand selection.

Q: Can the 3RT20161AN21 be substituted with the 3RT20161AN22 in an existing 220 VAC control circuit? A: Both parts share the same 220 VAC coil and base product number. The difference lies in auxiliary-contact polarity (1NO vs 1NC per catalog titles). Verify that the auxiliary-contact function (interlock, indication, orPLC signal) matches the desired logic before substitution.

Q: What is the maximum switching voltage for the power poles of the 3RT20161AN21? A: The data source did not provide a maximum switching voltage field. For three-phase AC motor or feeder applications this parameter is essential; consult the official Siemens datasheet for the 3RT2016 series before specifying.


Last updated: May 9, 2026