Skip to main content
3VA5217-5ED32-0AA0

3VA5217-5ED32-0AA0 Circuit Breakers | siemens

MPN3VA5217-5ED32-0AA0Compare · similar
Active · In production

3VA5217-5ED32-0AA0 (siemens) Circuit Breakers. Series SENTRON; Package Box; Actuator Type Lever. RFQ for MOQ and lead time.

PackagingBox
Volume pricing1+ $1,630.23000
StockOut of Stock

Specifications

3VA5217-5ED32-0AA0 Technical Specifications - Column 1
ParameterValue
SeriesSENTRON
PackageBox
Actuator TypeLever
Number of Poles3
Current Rating (Amps)175 A
3VA5217-5ED32-0AA0 Technical Specifications - Column 2
ParameterValue
StatusActive
MountingDIN Rail
Approval AgencyCCC, CE, CSA, UL489
Voltage Rating - AC690 V

Product details

Siemens SENTRON 3VA52 Molded-Case Circuit Breaker

3VA5217-5ED32-0AA0 Parameter Overview

ParameterValue
Current Rating175 A
Number of Poles3
Short-Circuit Rating35 kA
MountingDIN Rail
ActuatorLever
IlluminationNone
EncapsulationBox
ApprovalsCCC, CE, CSA, UL489
SeriesSENTRON
ManufacturerSiemens

The 3VA52 family covers frame sizes in the SENTRON line; the FTFM suffix designates front-terminal flat-bar (mechanical) termination for use with bus or cable connections. The NUT variant includes factory-installed mounting hardware for the terminal nut assembly.

Compare: Seed vs Catalog Alternates

The reader must independently qualify the following alternatives against application requirements. Similarity scores reflect catalog-parameter proximity only and do not constitute interchangeability or approval equivalence.

Spec3VA5217-5ED32-0AA03VA5217-5ED32-1AA03VA5217-5ED36-0AA03VA5217-5ED31-0AA0
Poles3333
Current (A)175175175175
MountingDIN RailDIN RailDIN RailDIN Rail
ActuatorLeverLeverLeverLever
ApprovalsCCC, CE, CSA, UL489CCC, CE, UL489CCC, CE, CSA, UL489CCC, CE, CSA, EAC, UL489, VDE
Similarity1.01.01.0
  • 3VA5217-5ED32-1AA0: Shares 3-pole / 175 A / DIN Rail; differs by omitting CSA; ships with NAV label designation (visual indicator variant).
  • 3VA5217-5ED36-0AA0: Matches seed on poles, rating, and approvals; AL suffix indicates aluminum terminal material instead of copper-alloy flat bar.
  • 3VA5217-5ED31-0AA0: Retains 3-pole / 175 A / DIN Rail; carries additional EAC and VDE certifications and is flagged RoHS non-compliant.

3VA52 Family Pole-Count and Certification Variants

The 3VA52 series uses a structured MPN scheme where digit positions encode pole count and approval bundle. Panel builders selecting based on branch-circuit count should cross-reference the specific suffix against local authority requirements.

  • 4-pole variant: 3VA5217-5ED41-0AA0 extends to four poles while retaining 175 A and DIN Rail mounting; useful for three-phase with neutral protection or ground-fault coordination.
  • 2-pole variant: 3VA5217-5ED61-0AA0 provides a 2-pole option in the same frame, suitable for single-phase loads within the same current and short-circuit ratings.
  • FTAM base variant: 3VA5217-5EC32-0AA0 shares the 175 A / 3-pole / DIN Rail profile with FTAM front-terminal alternative mounting configuration; check mechanical dimensions for existing panel layouts.

Selection Criteria for SENTRON Frame Sizing

Rated current of 175 A places the 3VA52 at the upper end of standard DIN-rail-compatible molded-case breakers. Thermal-magnetic trip units handle typical industrial distribution loads; verify coordination with upstream protective device and downstream cable ampacity. Frame thermal ratings assume ambient conditions per UL 489; enclosed panel temperatures may require derating per Siemens derating curves.

Frequently asked questions

Lead time / allocation notes for 3VA5217-5ED32-0AA0 (3VA5217-5ED32-0AA0)?

siemens line card data is a snapshot. Ships quickly when in stock; otherwise lead time follows distributor or factory lots. Lock dates on your PO or distributor confirmation.

What can substitute for 3VA5217-5ED32-0AA0 if supply tightens?

We narrow candidates from footprint, voltage/current class, and approvals visible on this page. Any change still needs your datasheet review and hardware qualification—not a guaranteed substitute from storefront text.

Is 3VA5217-5ED32-0AA0 appropriate for my panel design?

We start from the values printed in the specification table, then ask for one-line diagrams or net names that matter for your branch.

Who can validate 3VA5217-5ED32-0AA0 against my schematic?

Start from this page’s spec snapshot, attach your critical nets, and request a structured comparison on RFQ.

What does this page list for “Current Rating (Amps)” on 3VA5217-5ED32-0AA0?

The storefront table shows **Current Rating (Amps)**: 175 A. Treat it as a catalog snapshot—re-verify safety-critical ratings on the current manufacturer datasheet.

Compare

Parametric matrix links; verify on the datasheet before BOM swaps.

N-way (8 parts) · columns 2+ sorted by Hub similarity to 3VA5217-5ED32-0AA0

Technical resources

Lifecycle: Active