Parameter6SL32165BE175CV06SL32201YC401UF0
Operating temperature10°C to 60°C20°C to 45°C
Load Voltage400 to 480 V200 to 240 V
Supply voltage380 to 480VAC200 to 240VAC
For Use With/related ProductsSINAMICS SeriesG120X Series
Load Power750 W55000 W
Output Current2.2 A260 A

Table lists differing catalog rows only; highlight calls attention to the delta cells.

Catalog selection insight

One-line delta from headline spec rows — screening language only, not a suitability or substitution decision.

6SL32165BE175CV0: supply / I/O voltage headline differs from 6SL32201YC401UF0 (400 to 480 V vs 200 to 240 V) — re-check fuse sizing, surge rating, and SELV/PELV boundaries. 6SL32165BE175CV0: headline supply differs from 6SL32201YC401UF0 — treat as a different electrical platform until PSU, protection, and I/O are revalidated (not a same-rail swap by catalog text alone).

Technical screening notes (catalog snapshot)

Deterministic text from normalized spec keys — not live field-application-engineering advice or manufacturer sign-off.

Technical screening note for 6SL32165BE175CV0 vs 6SL32201YC401UF0: this catalog snapshot lacks obvious isolation/EMC/protocol rows — expand the PDP specification table or open the PDF for creepage, surge, and bus timing before any design change.

Catalog screening tiers (heuristic)

Three non-authoritative screening tiers (mechanical token, functional checklist, planning notes) mirror the JSON-Ld ItemList on this page — not manufacturer substitution letters or field approvals.

  • Mechanical / packaging row (not interchange)

    Headline rows in this catalog snapshot differ on supply, fieldbus/protocol, and/or compute — **do not** read that as interchange, drop-in, or “safe substitute” from distributor text alone. Packaging or mechanical tokens also differ or are too generic to infer fit — treat as independent SKUs until qualified in your system.

    Warning: Supply / IO voltage text differs (380 to 480VAC vs 200 to 240VAC).

  • Functional screening checklist

    Run isolation, supply, bus timing, software/runtime, and mechanical checks against your deployed baseline. Catalog differences above block any “equivalent part” claim from this page.

    Warning: Supply / IO voltage text differs (380 to 480VAC vs 200 to 240VAC).

  • Design-change planning notes

    If you intend a product change, favor wider temperature, higher isolation withstand, or newer fieldbus only **after** manufacturer guidance, software licensing, and enclosure clearance are confirmed — not from this matrix alone.

6SL32165BE175CV0 vs 6SL32201YC401UF0

Tool-style compare: isolation, supply, IP, rail, fieldbus, and EMC rows are surfaced first when present. Open each PDP for PDF revisions and RFQ.

Compatibility screening (catalog text)

Same deterministic tiers as the compare module above — for engineering checklists only, not approved alternates. Supply, protocol, and processor headline mismatches surface as warnings when present.

  1. 1. Mechanical / packaging row (not interchange)

    Headline rows in this catalog snapshot differ on supply, fieldbus/protocol, and/or compute — **do not** read that as interchange, drop-in, or “safe substitute” from distributor text alone. Packaging or mechanical tokens also differ or are too generic to infer fit — treat as independent SKUs until qualified in your system.

  2. 2. Functional screening checklist

    Run isolation, supply, bus timing, software/runtime, and mechanical checks against your deployed baseline. Catalog differences above block any “equivalent part” claim from this page.

  3. 3. Design-change planning notes

    If you intend a product change, favor wider temperature, higher isolation withstand, or newer fieldbus only **after** manufacturer guidance, software licensing, and enclosure clearance are confirmed — not from this matrix alone.

Technical compliance & certifications

Values below are extracted from normalized catalog specification keys and brand-level certification lists (where present). They mirror manufacturer datasheet legends when those strings were captured in the catalog row — not a certificate download. This page was machine-aligned on 2026-05-10 for technical selection support only; it is not the sole basis for installation or safety sign-off in your jurisdiction.

6SL32165BE175CV0

  • RoHS / restricted substances statements

6SL32201YC401UF0

  • RoHS / restricted substances statements