Skip to main content

6EP13225BA10 vs 6EP13361LB00 — parameter matrix

Comparison matrix

Industrial parameter delta view (differing rows only). Toggle highlight to stress changed cells for cabinet retrofit reviews.

Normalized specification differences for 6EP13225BA10 and 6EP13361LB00
Parameter6EP13225BA106EP13361LB00
Operating temperature20°C to 70°C (With Derating)-
Ac Voltage - Input100 to 230 VAC, 85 to 264 VAC-
Dc Voltage - Input (max)300 V-
Dc Voltage - Input (min)110 V-
Input Voltage Ac-100 ~ 240 VAC, 85 ~ 264 VAC
Voltage - Output 112 V-
Voltage Output-24V
PackageBulk-
Size / Dimension3.94" L x 2.07" W x 3.15" H (100.0mm x 52.5mm x 80.0mm)-
ApprovalsCB, cCSAus, CE, CSA, cUL, cULus, ULCB, CE, CSA, cUL, cULus, UL
Current - Output (max)6.5 A-
Current Output-20A
Efficiency86%92%
Min Order Qty-1
Power-480W
Power (watts)78 W-
RohsROHS3 Compliant-
Rohs Status-RoHS non-compliant
Standard Number60950-1; UL 508-
Standards-60950-1; UL 508
StatusActive-

Table lists differing catalog rows only; highlight calls attention to the delta cells.

Catalog selection insight

One-line delta from headline spec rows — screening language only, not a suitability or substitution decision.

6EP13225BA10: supply / I/O voltage headline differs from 6EP13361LB00 (100 to 230 VAC, 85 to 264 VAC vs 24V) — re-check fuse sizing, surge rating, and SELV/PELV boundaries. 6EP13225BA10: headline supply differs from 6EP13361LB00 — treat as a different electrical platform until PSU, protection, and I/O are revalidated (not a same-rail swap by catalog text alone).

Technical screening notes (catalog snapshot)

Deterministic text from normalized spec keys — not live field-application-engineering advice or manufacturer sign-off.

Mechanical fit: 6EP13225BA10: 3.94" L x 2.07" W x 3.15" H (100.0mm x 52.5mm x 80.0mm); 6EP13361LB00: none. Rail width and module depth govern retrofit — measure the existing carrier before assuming plug-and-play mechanical interchange.

Catalog screening tiers (heuristic)

Three non-authoritative screening tiers (mechanical token, functional checklist, planning notes) mirror the JSON-Ld ItemList on this page — not manufacturer substitution letters or field approvals.

  • Mechanical / packaging row (not interchange)

    No substantive shared package token — treat as independent mechanical designs, not a hot swap, until your own checks pass.

  • Functional screening checklist

    Run isolation, supply range, bus timing, and software/runtime checks against your deployed baseline. Matching tokens here do **not** prove interchange — only your qualification tests do.

  • Design-change planning notes

    If you intend a product change, favor wider temperature, higher isolation withstand, or newer fieldbus only **after** manufacturer guidance, software licensing, and enclosure clearance are confirmed — not from this matrix alone.

6EP13225BA10 vs 6EP13361LB00

Tool-style compare: isolation, supply, IP, rail, fieldbus, and EMC rows are surfaced first when present. Open each PDP for PDF revisions and RFQ.

Compatibility screening (catalog text)

Same deterministic tiers as the compare module above — for engineering checklists only, not approved alternates. Supply, protocol, and processor headline mismatches surface as warnings when present.

  1. 1. Mechanical / packaging row (not interchange)

    No substantive shared package token — treat as independent mechanical designs, not a hot swap, until your own checks pass.

  2. 2. Functional screening checklist

    Run isolation, supply range, bus timing, and software/runtime checks against your deployed baseline. Matching tokens here do **not** prove interchange — only your qualification tests do.

  3. 3. Design-change planning notes

    If you intend a product change, favor wider temperature, higher isolation withstand, or newer fieldbus only **after** manufacturer guidance, software licensing, and enclosure clearance are confirmed — not from this matrix alone.

Technical compliance & certifications

Values below are extracted from normalized catalog specification keys and brand-level certification lists (where present). They mirror manufacturer datasheet legends when those strings were captured in the catalog row — not a certificate download. This page was machine-aligned on 2026-05-12 for technical selection support only; it is not the sole basis for installation or safety sign-off in your jurisdiction.

6EP13225BA10

  • UL / CSA class listings (verify file number on certificate)
  • CE / EU declaration cues in datasheet or packaging legend
  • RoHS / restricted substances statements

6EP13361LB00

  • UL / CSA class listings (verify file number on certificate)
  • CE / EU declaration cues in datasheet or packaging legend
  • RoHS / restricted substances statements