{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"VO3063-X006","brand":"Vishay","brandSlug":"vishay","productSlug":"VO3063-X006","canonicalUrl":"https://icboms.com/vishay/VO3063-X006","factsUrl":"https://icboms.com/api/mcp/products/VO3063-X006","rawCanonicalId":null},"summary":{"shortDescription":"VO3063-X006 optoisolator with triac output, 5300Vrms isolation, 600 V off-state, 1.5 kV/µs min dV/dt, zero-crossing circuit, 6-DIP through-hole package, -55°C to 100°C, ROHS3 compliant, active lifecycle.","salesMarkdown":"## Triac-output optoisolator for AC load switching The VO3063-X006 is a single-channel optoisolator with a triac output from Vishay, packaged in a 6-DIP through-hole package (0.400\" lead spacing). It provides 5300Vrms isolation between the LED input and the triac output, with a 600 V off-state voltage rating that suits direct switching of 120 VAC or 240 VAC resistive and inductive loads. The zero-crossing circuit turns on the triac near the AC zero-voltage point, reducing inrush current and EMI in heater, lamp, and motor-start applications. The part carries cUR and UR agency approvals, confirming its acceptance for North American safety-listed equipment. ## dV/dt immunity and false-trigger margin A minimum static dV/dt of 1.5 kV/µs means the triac will not falsely trigger from fast voltage transients on the AC line — a common failure mode when switching inductive loads like contactors, solenoids, or small motors. If your application sees repetitive snubber-less switching, this rating gives you a clean margin over the 200–500 V/µs transients typical in industrial 240 VAC environments. The 200 µA typical holding current keeps the triac latched once triggered, even with low-load currents down to a few milliamps. ## LED drive and on-state current budget The LED requires a maximum trigger current of 5 mA to turn on the triac, with a typical forward voltage of 1.2 V. Maximum continuous LED forward current is 60 mA. The triac itself is rated for 100 mA RMS on-state current, which covers low-power loads such as solid-state relays driving small valves, indicator lamps, or logic-level AC inputs. For loads above 100 mA, the VO3063-X006 should drive an external power triac or SSR. ## Temperature range and operating environment The 100°C ceiling is the junction limit — derate the on-state current above 70°C per the datasheet thermal derating curve. Storage temperature exceeds the operating range, so the part can survive handling in unheated warehouses. ## Lifecycle and compliance It is ROHS3 compliant.","metaTitle":"VO3063-X006 Optotriac, 5300Vrms, 600V Off-State, 6-DIP","metaDescription":"VO3063-X006 optoisolator with triac output, 5300Vrms isolation, 600V off-state, 1.5kV/µs dV/dt. Active lifecycle, ROHS3.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":"ROHS3 Compliant","productStatus":"Active","categoryPath":["Optoisolators"],"specifications":{"Package":"Tube","Output Type":"Triac","Mounting Type":"Through Hole","Package / Case":"6-DIP (0.400\\\", 10.16mm)","Approval Agency":"cUR, UR","lifecycle_stage":"eol_hot","Number of Channels":"1","Static dV/dt (Min)":"1.5kV/µs","Current - Hold (Ih)":"200µA (Typ)","Voltage - Isolation":"5300Vrms","Voltage - Off State":"600 V","Operating Temperature":"-55°C ~ 100°C","Zero Crossing Circuit":"Yes","Supplier Device Package":"6-DIP","Voltage - Forward (Vf) (Typ)":"1.2V","Current - DC Forward (If) (Max)":"60 mA","Current - LED Trigger (Ift) (Max)":"5mA","Current - On State (It (RMS)) (Max)":"100 mA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1.63","stockQuantity":0,"priceTiers":[{"qty":1,"price":"$1.63000","currency":"USD"},{"qty":10,"price":"$1.03300","currency":"USD"},{"qty":100,"price":"$0.76420","currency":"USD"},{"qty":500,"price":"$0.70226","currency":"USD"},{"qty":1000,"price":"$0.57833","currency":"USD"},{"qty":2000,"price":"$0.54941","currency":"USD"},{"qty":5000,"price":"$0.53702","currency":"USD"},{"qty":10000,"price":"$0.52462","currency":"USD"}]},"links":{"datasheetUrl":"https://cdn.icboms.com/44ddb73ebc064dec0a7bae0427f78424.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What is the maximum forward current and holding current of VO3063-X006?","answer":"Maximum DC forward current through the LED is 60 mA. The triac's typical holding current is 200 µA — the minimum load current needed to keep the triac latched after the LED is turned off."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://icboms.com/vishay/VO3063-X006","citationPolicyUrl":"https://icboms.com/llms.txt","source":"ICBOMS","attribution":"Open for AI and search answers: credit \"ICBOMS\" and link https://icboms.com/vishay/VO3063-X006 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-17T19:50:00.618Z","lastPublished":"2026-07-17T19:50:00.618Z","indexable":true}}