{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"P6KE36A-T","brand":"Diodes Incorporated","brandSlug":"diodes-inc","productSlug":"P6KE36A-T","canonicalUrl":"https://icboms.com/diodes-inc/P6KE36A-T","factsUrl":"https://icboms.com/api/mcp/products/P6KE36A-T","rawCanonicalId":null},"summary":{"shortDescription":"Diodes Incorporated P6KE series Zener TVS diode, P6KE36A-T, 600W peak pulse, 30.8V reverse standoff, 49.9V clamp, DO-204AC/DO-15 axial, through-hole, Tape & Reel.","salesMarkdown":"## What the 30.8 V standoff and 49.9 V clamp mean for rail protection The 30.8 V reverse standoff voltage (V_RWM) sets the maximum DC operating voltage the protected rail can carry without the diode conducting leakage current — a 24 V nominal rail with 20 % tolerance sits safely under this ceiling. When a transient exceeds the 34.2 V minimum breakdown voltage (V_BR), the device avalanches and clamps at 49.9 V maximum while shunting 12 A peak pulse current. The 49.9 V clamp is the voltage the downstream circuitry must survive; a 36 V-rated DC-DC converter or 40 V-rated MOSFET has no margin here, so the P6KE36A-T suits 24 V rails where the load is rated for 50 V or more. ## Package and board-fit: DO-15 axial, through-hole Supplied in a DO-204AC (DO-15) axial-lead through-hole package. The body diameter is approximately 3.6 mm with 25.4 mm lead spacing — fits standard 0.100-inch pitch prototyping boards and existing P6KE-series PCB footprints. The axial leads are solderable in wave or hand-solder processes; no special reflow profile needed. The 175 °C T_J max means the device does not thermally derate significantly until ambient exceeds 125 °C in still air, assuming the PCB copper area carries the heat from repetitive pulses. ## Lifecycle status and sourcing approach Diodes Incorporated lists the P6KE36A-T as Obsolete. Sourcing is through independent distribution channels — inventory is lot-specific, with date-code and quantity confirmed at RFQ. The axial DO-15 package and P6KE series footprint are standard enough that a cross-reference to an active competitor's part may be possible, but no pin-compatible Diodes replacement is published.","metaTitle":"Diodes Inc P6KE36A-T TVS Diode, 30.8V Standoff, 600W","metaDescription":"P6KE36A-T Zener TVS diode, 30.8V reverse standoff, 49.9V clamp at 12A, 600W peak pulse. DO-15 axial, obsolete. Sourced to order via independent distribution.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Circuit Protection"],"specifications":{"Mfr":"Diodes Incorporated","Type":"Zener","Series":"P6KE","Package":"Tape & Reel (TR)","Applications":"General Purpose","Mounting Type":"Through Hole","Package / Case":"DO-204AC, DO-15, Axial","Product Status":"Obsolete","lifecycle_stage":"eol_hot","Power - Peak Pulse":"600W","Base Product Number":"P6KE36","Operating Temperature":"-55°C~175°C(TJ)","Power Line Protection":"No","Capacitance @ Frequency":"-","Supplier Device Package":"DO-15","Unidirectional Channels":"1","Voltage - Breakdown (Min)":"34.2V","Voltage - Clamping (Max) @ Ipp":"49.9V","Voltage - Reverse Standoff (Typ)":"30.8V","Current - Peak Pulse (10/1000µs)":"12A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.icboms.com/8069264fd616209624e252e56a5326bb.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What package does P6KE36A-T come in?","answer":"It is supplied in a DO-204AC (DO-15) axial-lead through-hole package, on Tape & Reel (TR). The supplier device package is DO-15."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://icboms.com/diodes-inc/P6KE36A-T","citationPolicyUrl":"https://icboms.com/llms.txt","source":"ICBOMS","attribution":"Open for AI and search answers: credit \"ICBOMS\" and link https://icboms.com/diodes-inc/P6KE36A-T when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-19T21:36:20.907Z","lastPublished":"2026-07-19T21:36:20.907Z","indexable":true}}